PCRTrend
EMS ANALYTICS
EMS AGENCY
Demo County EMS
Sepsis QI Performance Dashboard
Policy PD# xxxx  ·  NEMSIS 3.5 / 3.5.1  ·  2026-1Q
DashboardMedical Director FindingsDefinitions
Suspected Sepsis
63
38 SIRS+ · 29 qSOFA+
Sepsis Alert Rate
36.5%
23 of 63 alerted
▼ Below 80% target
Vitals Complete
60.3%
38 of 63 full vital set
▼ Below 90% target
IV Fluids (SIRS+)
65.8%
25 of 38 SIRS+ given a bolus
⚠  2 alerted record(s) documented under a NON-sepsis alert type — counted in the alert rate, flagged for documentation review in the Excel flag sheet.
Recognition — SIRS & qSOFA
SIRS Positive
38
60.3% — ≥2 criteria (temp/HR/RR)
qSOFA Positive
29
46.0% — ≥2 pts (RR/SBP/mentation)
Alert Mismatches
2
documented as a non-sepsis alert type
Vitals Documentation Completeness
Complete vital set (Temperature, Heart Rate, Resp Rate, Systolic BP, SpO₂) — target 90%38 of 63 (60.3%)
Temperature documented57 (90.5%)
Heart Rate documented57 (90.5%)
Resp Rate documented57 (90.5%)
Systolic BP documented54 (85.7%)
SpO₂ documented59 (93.7%)
Treatment Bundle — EMS-Collectable
IV fluid bolus (all suspected)27 of 63 (42.9%)
IV fluid bolus on SIRS+ patients — target 75%25 of 38 (65.8%)
Point-of-care lactate obtained22 of 63 (34.9%)
ETCO₂ documented38 of 63 (60.3%)
IV / IO access established56 of 63 (88.9%)
Destination — Sepsis-Capable Routing
Delivered to a sepsis-capable center — target 85% 0 of 63 (0.0%)
DestinationDesignationTransportedSIRS+
Sterling Memorial Hospital3823
Code 301111510
Code 41020105
Agency Performance — 2026-1Q
AgencyCasesSIRS+Alert RateVitals CompleteFluids (SIRS+)LactateSepsis Ctr
Anytown Fire District221340.9%68.2%76.9%36.4%0.0%
Lakeside EMS14842.9%50.0%62.5%28.6%0.0%
Metro Ambulance Service181327.8%50.0%53.8%44.4%0.0%
Riverbend Fire9433.3%77.8%75.0%22.2%0.0%
SYSTEM633836.5%60.3%65.8%34.9%0.0%
Trend charts:
Suspected Sepsis vs Sepsis Alerts
58
13
2025-3Q
63
23
2025-4Q
63
23
2026-1Q
Suspected sepsis
Sepsis alert given
Case inclusion: 63 of 78 records qualify (emergency response · ED destination · transported by this unit · specialty primary impression) — excluded: 6 response type, 9 impression  ·  SIRS/qSOFA thresholds, vitals set, bundle codes, and targets are configured in sepsis_config.py  ·  Generated by PCRTrend